Send the weight to the POS

By default the scale only sends weight data to the POS when the POS requests it. This will tell you how to configure the scale to send the weight data to the POS as soon as the scale has "stabilized". Follow the instructions and images below.

Go in to SETUP mode by pressing and holding the HOLD and ZERO buttons for about three seconds. You should see CONFG on the screen.

Press the UNIT button until the screen changes to USEr. Press TARE to continue.

Press the UNIT button until you see the Con1 screen. Press TARE to continue.

Press the UNIT button until you see the oUtnd screen. Press TARE to continue.

Press the UNIT button until you see the StAbl screen. Press TARE to continue.

Press the ZERO three times to back out, at the Exit screen press TARE.

Last updated